9
4.4 Approvals
ISO8846;EMCDirective2004/108/EC;CEapprovedforelectromagneticcompatibility
5 Components (g.
1
,page2)
Ref Description Item Number(NorthAmerica/Europe)
1 Replacement key 385311036 / 860003853110362
2 Switch assembly 385311610 / 860003853116104
3
DTD02panelcover,black
DTD02panelcover,white
385311674 / 860003853116740
385311675 / 860003853116757
4 #6 fastener 385311612 / 860003853116120
5 Mounting frame 385311613 / 860003853116138
6
DTD02circuitass’y,12VDC
DTD02circuitass’y,24VDC
(includesitem5)
385311676/860003853116765–12VDC
385311677/860003853116773–24VDC
6 Installation
6.1 Tank discharge control panel (g.
2
,page2)
DTD02 Panel Template
Dimensions (g.
8
,page5)
Ref. Dimension
A 3.25 in. / 83 mm
B 3.25 in. / 83 mm
C 2.63 in. / 67 mm
D 2.63 in. / 67 mm
E 2.16 in. / 55 mm
F 2.69 in. / 68 mm
G 0.10 in. / 2 mm dia.
H Cut-out area.
Allow2in./51mm
clearance behind
wall.
Caution!
DonotinstallDTD02panelinanatmospherewith
potentiallyammableorexplosivevapors.
1. Select panel location away from direct contact with water
and oil.
2. Conrm clearance for wire connections behind wall, hull
liner or bulkhead.
3. Usingcontrolpaneltemplate(g.
8
,page5),cutout
panelaccesshole(E,F)anddrillfastenerholes(G).
4. With electrical power off, route wire from power source,
throughcircuitbreakerorfuse(notprovided),topanel
location. Route additional wires from discharge pump,
seacockrelayand“fulltank”probeaccordingtodiagram
on page 3 or 4, depending on your application, to panel
location(seeSection6.2or6.3,wiringdiagramkey).Make
sure wires extend out through panel access hole.
5. Make proper wiring connections to wires extending from
bottom of circuit assembly (g.
2
4,page2).
6. Remove panel cover (g.
2
1,page2)frommounting
frame(2)bycarefullypullingthemapart.Makesurewiresbetweenkeyswitch(3)andcircuit
assembly(4)remainattached.(Keypin1–red;pin2–brown;pin7–blue)
7. Installmountingframetowallwithfourfasteners(5).
8. Tuck key switch wires into circuit assembly housing, and push panel cover onto mounting frame
until it locks into place.
9. Turn on electrical power.
Dometic Tank Discharge Control Specifications