11
Dometic Tank Discharge Control Operation
7 Operation
Caution!
Operator must know local regulations for emptying a holding tank.
7.1 DTD01A discharge control with DTM04 tank monitor system (g.
4
, page 3)
1. When boat is in unrestricted waters and automatic pump-out is desired, open seacock, insert
keyintoswitchandturnto“automaticpower”position(A).
2. Asholdingtankcontentlevelincreasesandraisesthe“mid”leveloat,thedischargepump
starts(B).Agreen“tankdischarge”lightindicateswhenthedischargepumpisoperating.
3. Whentankcontentlevelfallsbelowthe“low/empty”probe,thepumpautomaticallystops
operating (C).
4. Ifpump-outisdesiredbutthe“mid”leveloathasnotactivatedthedischargepump,turnthe
keytothe“manualstart”position(B1).Holdthekeyuntiltankdischargeiscomplete,thenlet
keyreboundto“off”position.
Caution!
Donotallowdischargepumptooperateforanextendedperiodoftimewhenthereisno
dischargefromholdingtank.Damagetopumpmayresult.
7.2 DTD02A discharge control panel with DTM04 tank monitor system
(g.
5
, page 3)
1. When boat is in unrestricted waters and automatic pump-out is desired, open seacock, insert
keyintoswitchandturnto“automaticpower”position(A).
2. Ifseacockisclosed,theinterlockswitchsendsasignaltothepanel,theyellow“caution”
indicator turns on, and the discharge pump will not start. To start discharge pump with key in
“automaticpower”position,opentheseacock,andpumpwillstart(B).Agreen“tankdischarge”
light indicates when the discharge pump is operating.
3. Whentankcontentlevelfallsbelowthe“low/empty”probe,thepumpautomaticallystopsoper-
ating (C).
4. Ifpump-outisdesiredbutthe“mid”leveloathasnotactivatedthedischargepump,turnthe
keytothe“manualstart”position(B1).Holdthekeyuntiltankdischargeiscomplete,thenlet
keyreboundto“off”position.
Comentários a estes Manuais