Sealand DVF1619 Vent Filter Manual do Utilizador Página 3

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 2
3
Caution!
Do not use Dometic
®
Vent Filter for holding tanks with waste that is treated through on-
board sewage treatment systems that use chlorine or other strong oxidizing agents.
Install new filter
1. Select location for vent lter. Avoid areas near excessive heat sources (engine manifolds, lights, etc.).
Do not install lter below top of holding tank (g. page 2).
2. Vent lter can be mounted at any angle. Installations near thru-hull vent reduce chance of lter
damage from potential overlling of tank.
3. Install mounting bracket (g. 1, page 2) with fasteners (g. 2, page 2).
4. Press vent lter (g. 6, page 2) into mounting bracket.
5. Install 5/8-inch or 3/4-inch (16 mm or 19 mm) hose adapters (g. 4, page 2) on both ends of
lter, making sure rubber gaskets (g. 5, page 2) are in place. Tighten 1/4 to 1/2 turn beyond
hand tight.
6. Using hose clamps (g. 3, page 2) (not included with vent lter), install 16 mm or 19 mm
(5/8-inch or 3/4-inch) I.D. vent hoses (g. 2, page 2) from holding tank and thru-hull tting
(g. 1, page 2) to hose adapters on lter.
Remove old filter
(if replacing existing vent lter)
1. Remove vent hose from both ends of old vent lter.
2. Remove old lter from bracket and seal ends with caps that are provided with new lter.
3. Discard old lter in appropriate container.
2 General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
• Faultyassemblyorconnection
• Damagetotheunitfrommechanicalinuences
• Alterationstotheunitwithoutexpresswrittenpermissionfromthemanufacturer
• Useforpurposesotherthanthosedescribedintheoperatingmanual
Dometic Vent Filter General safety instructions
3 Intended use
Whenatoiletisushedonaboatwithaholdingtank,airispushedoutoftheholdingtank,through
a vent hose, and out of the boat through a vent tting. To stop foul-smelling air from coming out of
the vent tting, install a Dometic Vent Filter.
4 Installation
1
22
Caution!
Replaceventlterimmediatelyifaccidentaloverowofholdingtankoccurs.
Note
Replace vent lter at the beginning of each boating season for best odor control.