10
Operation Dometic Vacuum Status Control Panel
7 Operation
7.1 Vacuum status monitor (g.
3
, page 2)
1. WhenpowerswitchisturnedON,thegreen light indicates that there is sufcient vacuum in the
VacuFlushsystemtoushthetoilet(A).
2. WhenpowerswitchisturnedONandthered light glows, this indicates that there is NOT sufcient
vacuuminthesystemtoushthetoilet(B).Do not flush toilet, or blockage may occur in system.
Notes
Ifgreenandredlightconstantlycycleonandoffbetweenushes,thereisapossible
vacuumleakinthesystem.(AnidleVacuFlushsystemshouldnotcyclemorefrequently
than once every three hours.)
If green light is ON but there is no vacuum in system, a blockage has likely occurred
betweenthetoiletandvacuumtank.Openushballintoiletbowlandusestandardtoilet
plunger to unblock.
After a period of time, if red light seems to remain lit longer than when toilet system was
new, duckbill valves in vacuum pump may require replacement.
Caution!
IfDVS02isconnectedtoa“fulltank”sensorandholdingtankisempty,acontinuousred
light may indicate extensive vacuum loss due to blockage, pump failure or leak. Turn off
vacuum system and repair as soon as possible.
7.2 “Full tank” monitor (onlywhen connected to “full tank” sensor in waste holding tank)
1. WhenpowerswitchisturnedON,theredlightglows,andthevacuumpumpisnotrunning,this
indicates that the holding tank is full and needs to be pumped out. Do not flush toilet, or blockage
may occur in system.
7.3 Circuit breaker control (g.
3
, page 2)
1. TurnthepowerswitchtotheONposition(A,B)fornormaltoiletoperation.Onelightwillalwaysbelit
toindicatethereispowertotheVacuFlushtoiletsystem.Allowsystemvacuumtofullyrechargeand
green light to illuminate before turning power OFF for any reason.
2. Duringthenightorotherextendedperiodswhenthetoiletorvacuumsystemisnotneededto
operate,turnthepowerswitchtotheOFFposition(C).
Vista de página 9