3
U.S. (Metric)
Volume ......................................................... Up to 15.2 GPM ...................... (57 LPM)
Discharge Pressure......................................... Up to 1600 PSI-Continuous ....... (110 Bar)
..................................................................... Up to 1900 PSI-Intermittent
*
..... (131 Bar)
Inlet Pressure ................................................ Up to 90 PSI............................ (6.2 Bar)
Speed ............................................................................................................ Up to 1085 RPM
Plunger Diameter.......................................... 1.2 ......................................... 30mm
Plunger Stroke .............................................. 1.0 ......................................... 26mm
Crankcase Oil Capacity ................................ 32 fl.oz.................................... (0.9 liters)
Temperature of Pumped Fluids ..................... Up to 160
o
F ............................ (71
o
C)
Inlet Ports ...................................................................................................... (2) 1" NPT
Discharge Ports ............................................................................................. (2) 3/4" NPT
Pulley Mounting ............................................................................................ Either side
Shaft Rotation............................................... Top of Pulley Towards Fluid End
Weight .......................................................... 72 lbs. ..................................... (33kg)
Crankshaft Diameter ...................................................................................... 28mm
Specifications
Model MP4130-3100
Consult the factory for special requirements that must be met if the pump is
to operate beyond one or more of the limits specified above.
*
NOTE: Intermittent duty use (e.g. sewer cleaning industry, etc.) The pump must be fed with a 1" I.D.
hose from both inlet ports. If a Y-piece fitting is being used on the inlet, the "Y" must be fed
with a 1 1/2 " I.D. hose. All inlet lines must have practically no restrictions. Also, only cold
water should be used.
PULLEY INFORMATION
Pulley selection and pump speed are based on a 1725 PRM motor and "B" section belts. When selecting
desired GPM, allow for a ±5% tolerance on pumps output due to variations in pulleys, belts and motors among
manufacturers.
1. Select GPM required, then select appropriate motor pulley from the same line.
2. The desired pressure is acheived by selecting the correct nozzle size that corresponds with the pump GPM.
HORSEPOWER RATINGS:
The rating shown are the power requirements for the pump. Gas engine power outputs must be
approximately twice the pump power requirements shown above.
We recommend a 1.15 service factor be specified when selecting an electric motor as the power
source. To compute specific pump horsepower requirements, use the Following formula:
HP = (GPM X PSI) / 1440
MP4130W PULLEY SELECTION AND HORSEPOWER
REQUIREMENTS
PUMP
PULLEY
MOTOR
PULLEY
RPM GPM 500 PSI 1000 PSI 1500 PSI 1900 PSI*
9.75" 3.95" 660 9.0 3.1 6.2 9.4 11.9
9.75" 4.25" 715 10.0 3.5 6.9 10.4 13.2
9.75" 5.25" 900 12.6 4.4 8.8 13.1 16.6
9.75" 5.95" 1030 14.4 5.0 10.0 15.0 19.0
9.75" 6.25" 1085 15.2 5.3 10.6 15.8 20.1
9.75" 6.75" 1200 16.8 5.8 11.7 17.5 22.2
9.75" 7.35" 1300 18.2 6.3 12.6 19.0 24.0
*Intermittent Duty Only
MP4130-3100 PULLEY SELECTION AND
HORSEPOWER REQUIREMENTS